ATK

Turnout Switch Rods and Stretcher Bars

Turnout switch rods and stretcher bars

Switch rod, stretcher bar and connecting rod

Limiting stopper and anti-jump device

Top iron for lateral web support

Insulated rods for track circuits

End fittings to the switch machine

Rod position ±5 mm per TB/T 3434

4 mm no-lock criterion

Request a quotation

Turnout Switch Rods and Stretcher Bars

A turnout does not change route because someone pushes a rail. It changes because a rod moves two tapered blades into position and a lock holds them there. The rods are small parts in a large assembly, but they carry the geometry that decides whether a route is shown and whether a wheel is guided. The assembly covers the switch rod, the stretcher bar, the connecting rod, the limiting stopper, the anti-jump device and the top iron — ordered together, because they are adjusted together.

Overview

The switch assembly has three jobs: move the blades, keep them at a fixed separation while they move, and stop them travelling too far. Each job has its own member.

The switch rod links a blade to the switch machine or switch stand. An stretcher bar links the left blade to the right one, so both move as a pair. A connecting rod is the term used in some designs for a rod between the blades or between a rod and a moving point; a limiting stopper controls longitudinal over-travel of a blade against its stock rail. On top of the slide plates sit the anti-jump device, which stops a displaced blade lifting off its seat, and the top iron, which takes lateral load at the web without being a fastening in its own right.

Names vary between standards and between workshops. TB/T 1353-2020 gives switch rod, connection bar / following stretcher bar, and limiting stopper. EN 13232 and North American practice use stretcher bar for the member between the blades; North American switch plans also separate the head rod and the back rod by position, and call the drive member a pull rod. A buyer searching any of these names is usually looking for the same functional group.For the full naming split and what to put in an enquiry, see switch rod vs stretcher bar.

Three switch rods between turnout blades with limiting stopper and top iron

What Each Part Does

Switch rod. It transmits the throw from the machine to the blade. Its length sets the position of the blade when the machine is at its end position, so a rod an inch too long leaves the blade short of its stock rail even though the machine has fully stroked. Insulated versions are specified where the rod sits in a track circuit.

Stretcher bar. It ties the two blades together. Without it, one blade could lag the other and the pair would no longer present a consistent gauge through the switch. On a long or curved switch there may be more than one stretcher bar, and their positions are part of the switch design.

Connecting rod. In Chinese terminology the connection bar joins the two blades; in North American supply lists connecting rods are also offered as replacement pieces for particular switch plans. The order should state which position on the drawing the rod occupies, because rods of similar appearance are not interchangeable.

Limiting stopper. It sits between the blade and the stock rail and limits how far the blade can move longitudinally under thermal expansion or traffic. It is not an adjustment device: its position is set by the drawing, and a blade that needs repeated adjustment is telling you something else has moved.

Anti-jump device. Fitted on the slide plate, it prevents the open blade from riding up over the plate under a passing wheel. It matters most where the displaced blade is exposed to traffic.

Top iron. A block against the rail web, not through it. On a turnout it supports the rail laterally without adding a hole; a gap that grows beyond the maintenance limit is a reason to repack or replace it, not to tighten a bolt.

Technical Specifications

Item

Value

Assembly

Switch rods, stretcher bars, connecting rods and associated stops

Standards referenced

TB/T 1353-2020 (terms), TB/T 3434-2016 (manufacture and tolerances), EN 13232-5, AREMA (American Railway Engineering and Maintenance-of-Way Association) practice

Rod forms

Solid, insulated, adjustable, forged or spring connecting rod to drawing

End fittings

Fork, lug, eye or clevis, matched to the switch machine or blade bracket

Insulation

Insulated rods and insulated gauge plates where the track circuit requires them

Rod position tolerance

±5 mm longitudinal installation position

Locking difference

2 mm maximum difference between the two sides of external locking

Opening tolerance

±10 mm at each pulling point

Supply form

Individual rods, matched sets, or complete switch assembly

North American names

Head rod, back rod, pull rod and gauge plate — position names on the switch plan

Marking

Position number, hand and rail section where the drawing calls for it

 

The tolerances above are from a Chinese manufacturing condition for turnout construction, reproduced in technical references. They are given for orientation; the project drawing governs the order.

Three switch rods between turnout blades with limiting stopper and top iron

Locking Geometry: the Four-Millimetre Rule

The critical check at a turnout is not whether the machine has moved. It is whether the blade is close enough to its stock rail for the lock to prove the route.

TB/T 3434-2016 states that at a locking point, where the gap between blade and stock rail reaches 4 mm or more, the locking mechanism must not lock and must not give a route indication. Between locking points the threshold is 5 mm: at that gap the indication must not be given either, and a gap-check device is required.For where that gap is measured and why it is not a tolerance, see the 4 mm rule at a turnout.

Those two numbers explain most of the adjustment work on a switch. A rod can be correctly fitted and still leave a gap if the stock rail has worn, the slide plates have settled, or the machine linkage has slack. Adjusting the rod to compensate hides the fault; the source of the gap has to be found.

The same standard sets the longitudinal position of the conversion rods to ±5 mm, the difference between the two sides of external locking to 2 mm, and the opening at each pulling point to ±10 mm. Together they define an assembly that either proves a route or does not — there is no middle setting.

Three switch rods between turnout blades with limiting stopper and top iron

Facing Point and Trailing Point

Direction changes the load. A wheel approaching from the toe — a facing point — pushes the blade against its stock rail and tends to keep the route shut. A wheel approaching from the heel — a trailing point — tends to force the blades apart. This is why a switch needs both a positive lock and enough restraint along the rods: the blades must stay shut in one direction and must not be pried open in the other.

A split switch, where a facing wheel enters the gap between blade and stock rail, is the serious case. The rods, stops and lock are all part of preventing it. Nothing in that chain is a cosmetic fitting.

Manufacturing and Inspection

Rods are cut to the length on the switch plan, the end fittings are forged or machined, and the holes are drilled from a datum end. Insulated rods add insulating sleeves and washers and are checked for electrical separation as an assembly, not as loose parts.

Inspection covers the length, the hole centres, the end-fitting geometry and the straightness of the bar. On a matched pair the two rods are checked together, because a difference between them shows up as uneven blade movement. Where the project calls for magnetic-particle inspection of the heel area, that is done on the blade, not on the rod.

A rod that has been heated and re-bent in the field is not treated as equivalent to a shop-made one. The hole centres move, and with them the blade position.

Installation and Adjustment

Installation starts with the switch bearers. These are the long sleepers under the moving panel, and the slide plates are seated on them. The switch machine is set at its correct stroke before the rods are connected. Connecting a rod to a machine that is already off-centre makes every later adjustment wrong.

The blade is then brought to the closed position and the gap checked at each pulling point. A gap that fails the 4 mm or 5 mm test is investigated at the stock rail, the slide plate and the machine linkage before the rod is touched. Fine adjustment comes last, and it is recorded so the next inspection can tell whether the setting has drifted.

Anti-jump devices and limiting stoppers are set to the drawing. They are not there to take up wear; a stop that is repeatedly re-set is evidence of movement elsewhere in the assembly.

Three switch rods between turnout blades with limiting stopper and top iron

Wear and Replacement

Rods wear at the pins and at the clevis ends, where repeated throw opens the holes into ovals. An oval hole changes the effective rod length by the amount of the elongation, and the blade no longer reaches the position the lock expects. That is why a worn rod is replaced as a rod, not packed out with washers.

The top iron and limiting stopper are checked for gaps. A top iron with a gap beyond the maintenance limit, or a stop that has been shimmed repeatedly, points to lateral movement in the rail or the slide plate. The maintenance figures used in Chinese practice put the top-iron-to-web gap below 2 mm and the blade-to-slide-plate gap below 2 mm, but the project standard governs.

Insulated rods are replaced as a set with their sleeves and washers. Mixing an insulated rod with a non-insulated fitting in a track circuit is not a minor substitution.

Customisation and Supply

Made to order: rod length, bar section, end-fitting type, hole centres, insulation, coating and position marking. Fixed by the switch design: the number and position of pulling points, the relationship between rods, the throw, and the lock arrangement.

Three switch rods between turnout blades with limiting stopper and top iron

For a quotation, send the switch plan number and hand, the rail section with track gauge, the switch length, the rod list, the machine type and clip arrangement, and whether the rods are insulated. For a replacement rod, add its position on the plan, length, end-fitting form and hole centres. A part number from the original plan is the safest reference; a photograph starts the review but does not replace the drawing.

Three switch rods between turnout blades with limiting stopper and top iron

FAQ

What is a switch rod?

The rod that links a switch blade to the switch machine or stand. Its length sets where the blade sits when the machine reaches its end position.

Is a stretcher bar the same as a connecting rod?

In many drawings they describe the same member between the two blades. TB/T 1353-2020 uses connection bar / following stretcher bar; EN 13232 and North American practice use stretcher bar.

Why are there three rods on some turnouts?

Because three functions are being performed: driving the blades, tying them together, and controlling over-travel. A longer switch may need more than one stretcher bar.

What does the four-millimetre rule mean?

At a locking point, a gap of 4 mm or more between blade and stock rail must prevent locking and prevent a route indication. It is a safety criterion, not a fitting tolerance.

What is the difference between a limiting stopper and an anti-jump device?

The stopper limits longitudinal movement of the blade. The anti-jump device, fitted on the slide plate, stops the open blade lifting. They act in different directions.

Is the top iron a fastening?

No. It sits against the rail web and takes lateral load without a hole through the web. It is inspected by the gap behind it.

Do you supply insulated switch rods?

Yes, with the specified sleeves, washers and end fittings. State the track-circuit arrangement so the insulation is checked as an assembly.

Can I order one rod as a spare?

Yes. Give the turnout number and hand, the rod position, the length and the end-fitting form. A part number from the original plan is the safest reference.

Can you make rods to our drawing?

Yes. Length, end fittings, hole centres, insulation and marking are made to the switch plan. Send the drawing with the rod positions numbered and the machine type identified.

What happens if the rod is adjustable?

An adjustable rod is supplied for the position the drawing assigns to it. It is set during commissioning and then locked; it is not a general-purpose replacement.

What tolerances do you work to?

Tolerances such as ±5 mm rod position and ±10 mm opening at each pulling point come from the cited manufacturing condition. The project drawing and standard govern the order.

Do you supply the switch machine as well?

No. The rods are made to couple to the machine specified on the plan. Send the machine type so the end fittings match.

Can you match an existing rod when the drawing is lost?

Yes, with measurements. Length, hole centres, end-fitting form and whether the rod is insulated are the minimum needed before manufacture.

What do you need to quote a replacement rod?

Give the plan number and hand first, then the rail section and track gauge, the rod position, length, hole centres and end-fitting form. State the machine type where the rod couples to the stand.

Related Equipment

At the blade end of the assembly sit the switch rails and stock rails. Blade movement is guided by the slide baseplate, and the fixing positions use spacer blocks and heel blocks. The complete turnout shows where this rod set belongs.

Inquiry

Rod lists are quoted against the switch plan. Mark the position of each rod, state the machine type and whether the set is insulated, then Request a quotation. End fittings are confirmed before manufacture.

Related Products