Separates switch rod from stretcher bar by function, then explains the naming split across TB/T 1353, EN 13232, North American position names and UK lock stretcher bar usage; swan neck insulation, oval-hole failure and an ordering checklist.

The switch rod and the stretcher bar sit side by side in that sketch, and the confusion is not carelessness. The same hardware is named by function in one standards system, by position in another, and by workshop habit in a third. The names need sorting out first, and then the enquiry has to say what the supplier should actually make.
A switch rod connects a switch blade to the operating machine or stand. It carries the throw — the push and pull that moves the blade.
A stretcher bar connects the two blades to each other. It does not drive anything. It keeps the pair at a fixed distance so they move together and arrive at the right gauge.
One applies force. The other keeps geometry. If you remember nothing else, remember that.
The machine strokes to its end position. The switch rod passes that movement to the blade, and its length decides where the blade finishes up. Get the length wrong and the blade stops short of the stock rail even though the machine has done its job. The lock may refuse to prove the route, or worse, prove it with a gap still there.
That is why a switch rod is never ordered by appearance. Length, hole centres and end-fitting form come from the switch plan, and the machine type has to be named so the fitting matches the drive. Track-circuit zones call for the insulated form of the rod.
Two blades have to move as a pair. Without a bar between them, one can lag the other, and the switch no longer presents a consistent gauge through the panel. The stretcher bar prevents that, and it also resists the tendency of the blades to sprawl as they throw.

Here is where a simple question stops being simple.
TB/T 1353-2020, the Chinese terminology standard for turnouts and crossings, defines the switch rod as the bar connecting the switch or movable-point crossing to the switch equipment. Its connection bar — also given as *following stretcher bar* — joins the two switch blades in a switch, or the two movable points in an obtuse crossing. So in that system, the drive rod and the inter-blade rod have different official names.
European drawings under EN 13232 generally call the inter-blade tie a stretcher bar. North American plans go a different way, labelling rods by where they sit: head rod, back rod, pull rod, gauge plate. One drawing names the function, the next names the location — same steel, different words.
Then there is the British usage, which is where genuine confusion starts. In UK practice the bar at the blade toes is connected to detection equipment that tells the interlocking whether the switch is correctly positioned; the arrangement is described as a lock stretcher bar and detector rods. Bars elsewhere on the switch are permanent way stretcher bars. A UK drawing saying "stretcher bar" may therefore mean the toe-end detection member, not the simple inter-blade tie an American supplier would picture.
System | Drive / lock member | Inter-blade member |
TB/T 1353-2020 | switch rod | connection bar / following stretcher bar |
EN 13232 practice | stretcher bar (context) | stretcher bar |
North American plans | pull rod, head rod | stretcher bar, gauge plate |
UK permanent way | lock stretcher bar | permanent way stretcher bars |
Read the position, not just the noun. A name alone cannot tell you which hole pattern to drill.

UK practice calls this arrangement a swan neck: the stretcher bar is made in two unequal lengths, joined through an insulated fitting. The bar still holds the blades at the correct distance, but the circuit stays split. A buyer who orders a plain bar for an insulated location has not saved money; they have created a signalling fault waiting to happen.
Insulated switch rods follow the same logic. State the track-circuit arrangement at enquiry so the sleeves, washers and end fittings are checked as an assembly rather than as loose parts.
Fasteners in these bars see repeated vibration from passing trains. Loose bolts and fractured bars are recognised failure modes in UK inspection regime, not hypotheticals.
The slower failure is harder to see. Wear at the pins and clevis ends opens the holes into ovals. Each millimetre of stretch shifts the effective length, and the blade stops short of where the lock expects it. Nothing looks snapped, but the setting has crept. A rod in that state gets replaced whole — washers cannot recover the lost geometry.
The same message comes from a limiting stopper that keeps needing re-setting. Its location is set on the drawing, not chosen on site. If it keeps moving, the cause lies somewhere else in the assembly.
A machine completing its stroke proves only that the machine moved. What matters at the blade is whether the gap is small enough for the lock to register a route.
TB/T 3434-2016 draws the line at two gaps. Where the lock sits, a 4 mm opening between blade and stock rail has to stop the mechanism from locking and stop it showing a route. Away from the lock points the figure rises to 5 mm, and a gap-check device is called for. Neither number is a fit setting — both are safety interlocks.
If a rod is correctly fitted and the gap still fails, the fault is upstream — a worn stock rail, settled slide plates, or slack in the machine linkage. Shortening the rod to close the gap hides the problem instead of fixing it. The check has to be made under power, not by hand.

· turnout number and hand, with the rail section and track gauge;
· the switch plan or rod list, with each rod's position marked;
· which positions are insulated;
· the machine type and the end-fitting form at each connection;
· for a replacement, the old rod's length, hole centres and fitting type.
A photograph is useful for starting the conversation. It is not a substitute for the drawing, because two rods that look identical can differ in hole pitch and in the end fitting that couples to the machine.
Where the original plan is available, a part number is the safest reference. Where it is not, the five measurements above are the minimum before manufacture.
No. The switch rod drives a blade from the machine. The stretcher bar ties the two blades together.
Standards differ. TB/T 1353 uses switch rod and connection bar; EN and North American plans use stretcher bar for the inter-blade member. Position wins over noun.
A UK term for the bar at the blade toes connected to the detection equipment; the full arrangement is the lock stretcher bar and detector rods. Other bars are permanent way stretcher bars.
It depends on the switch design. Longer switch rails on faster routes carry more bars; short slow-speed switches carry fewer.
As a replacement, yes, if the position and fitting match. The pair still needs its stretcher bars to keep the blades in step.
An insulated break built into a stretcher bar so the bar can tie the blades without shorting the track circuit. UK term.
Where the rod crosses a track circuit boundary, yes. State that at enquiry; the sleeves, washers and fittings then get checked together.
A photo starts the review. Length, hole centres and end-fitting form are needed before manufacture.
The gap may come from a worn stock rail, settled plates or linkage slack. The rod is only one link in that chain.Why that 4 mm gap stops the lock is explained in what the 4 mm rule means at a turnout.
TB/T 3434-2016 gives ±5 mm for longitudinal installation position, with the project drawing governing the order.
The parts named here belong to the wider switch assembly: the blades they move, the plates that guide them, and the turnout geometry that decides how many rods a design needs. Each is covered in its own guide on this site.
Send the switch plan or rod list with each position marked, the rail section, the machine type and whether the rods are insulated. Request a quotation with the drawing attached.