Product Details

ATK

What Is the 4 mm Rule at a Railway Turnout?

Explains the 4 mm locking-point and 5 mm inter-point criteria from TB/T 3434-2016: measurement locations, under-power checks, why they are safety interlocks not tolerances, gap causes and the separate maintenance figures.

A switch can be fully stroked, the machine can report end position, and the route still must not be shown. That sounds contradictory until you look at the gap: blade against stock rail, or point against wing rail in a movable-point crossing. If that gap has reached 4 mm at a locking point, the lock is required to refuse to close and the signal system must not receive a route indication.

The rule is easy to quote and easy to misapply. The numbers need to be read in context: what they mean, where they are measured, and why they are safety criteria rather than fitting tolerances.

The Two Numbers

The 4 mm rule is a detection rule: once the blade-to-stock-rail gap reaches 4 mm at a lock, the mechanism must refuse to close and the signal must stay clear of a route indication. Away from the locks the corresponding figure is 5 mm. Neither number describes how the switch is assembled.

TB/T 3434-2016, the Chinese manufacturing condition for turnout construction, sets those two thresholds:

· At a locking point — where the external locking gear acts — a gap of 4 mm or more between blade and stock rail, or point and wing rail, must prevent the locking mechanism from closing and prevent a route indication.

· Between locking points — a gap of 5 mm or more must prevent a route indication. A dedicated detector is required in that zone.

Read the wording carefully. These are not limits for how the switch should be assembled. They define when a switch must be treated as *not proven*. A lock that closes across a 4 mm gap is a lock giving a false indication of safety.

Why 4 mm Matters

The blade is a tapered rail that must lie against the stock rail to form a continuous running edge. When a gap opens, the wheel flange can enter it. At a facing point — where the train approaches from the toe — that can lead to a split switch, with the wheel taking a route the signal system has not authorised.

The consequence is not a small ride-quality issue. A split switch at speed is one of the serious failure modes in turnout operation. The 4 mm criterion exists to stop the signalling system from saying "route set" when the mechanical geometry is no longer good enough to guarantee it.

One qualification matters. The gap figure is not identical across every speed band or every switch plan. A separate conversion-equipment installation condition applies 4 mm at the first pulling point, 6 mm at remaining pulling points on some multi-point layouts, and 10 mm between pulling points on higher-speed arrangements. These are installation conditions for particular speed ranges, not alternatives to the 4 mm criterion discussed here. The governing drawing and standard always decide which set applies.

4 mm Rule at a Turnout: Locking and Detection

Where the Measurement Goes

A gap figure without a location is meaningless. The same switch can pass at one locking point and fail between points, and the two readings lead to different actions.

Measure at the centre line of each locking point for the 4 mm test — blade to stock rail, or point to wing rail where a movable-point crossing is fitted. The names on a drawing vary between standards, as the switch rod vs stretcher bar guide explains. Measure between locking points for the 5 mm test, where a dedicated detector is required. The distinction matters because the external lock and the intermediate detectors are different pieces of equipment, and the standard treats them separately.

The check is made with the switch under power, not by hand. A blade pushed closed by hand can sit differently from one moved and held by the machine, and the lock must be tested in the state in which it will actually be used.

Criteria Are Not Tolerances

This is where enquiries go wrong. The same standard also gives manufacturing and installation figures, and they are a different class of number:

The first three are things a fitter adjusts to. The last two are conditions that disqualify the route. Treating 4 mm as a tolerance to be "adjusted to" reverses the logic: the correct response is to find why the gap exists, not to shorten a rod until the lock happens to close.

What Actually Opens the Gap

A rod of the correct length can still leave a failing gap. The usual causes sit upstream of the switch rods and stretcher bars themselves:

· Worn stock rail or blade face. Material has been removed from the contact surfaces, so the blade travels the same distance but arrives short.

· Settled slide plates or bearers. The vertical and lateral position of the blade has shifted under traffic.

· Slack in the machine linkage. Some of the machine stroke is taken up before it reaches the blade.

· Thermal movement. Long rails expand and contract; the setting that was correct in spring may not be correct in summer.

Each of these needs a different remedy. Adjusting the rod to compensate for a worn rail hides the fault and leaves the underlying movement free to continue.

The Investment Case for Checking Properly

Inspection regimes treat this seriously. UK practice uses go/no-go gauges to test that facing point locks cannot allow the switches to open beyond the specified amount. The inspection pattern also measures clearances between switch and stock rails at the toe and around the back drive.

That approach has a commercial side too. A switch that repeatedly fails the gap test will be adjusted repeatedly, and each adjustment consumes a possession. Finding the settled plate or the worn contact face once is cheaper than re-setting the same rod every few weeks.

4 mm Rule at a Turnout: Locking and Detection

Maintenance Figures Are a Third Category

Below the safety criterion sit the working figures used in Chinese maintenance practice. A pulling point centre should hold no more than 0.5 mm, and between points no more than 1.0 mm. The top iron and blade foot each keep under 2 mm.

These are not the 4 mm rule. They are the condition a well-maintained switch is expected to hold, and they belong to operating maintenance rather than manufacturing acceptance. The governing standard for the project always takes precedence.

FAQ

What is the 4 mm rule at a turnout?

It is the detection criterion at a locked point: once the blade-to-stock-rail opening reaches 4 mm, the lock must refuse to close and no route may be shown. It is a safety rule, not a build tolerance.

Why 5 mm between locking points?

Because there is no external lock there. A detector is required, and at 5 mm or more the route indication must be suppressed.

Can I check the gap by hand?

No. The check has to be made with the switch under power, because a hand-pushed blade does not represent the working position.

If the gap is 4 mm, should I adjust the rod shorter?

Not first. Look at the stock rail, blade face, slide plates and machine linkage. Shortening the rod hides the cause.

What is a split switch?

A facing wheel entering the gap between blade and stock rail and forcing the blade open. The 4 mm criterion exists to stop a route being indicated in that condition.

What detector is used between locking points?

A device that verifies blade position where there is no external lock. TB/T 3434-2016 calls it a close-contact detector; point detector is the common English term.

Does the 4 mm figure apply to every turnout?

No. Installation conditions vary by speed band and by pulling-point position. The project drawing and governing standard decide.

Are the ±5 mm and ±10 mm figures the same as 4 mm?

No. Those are installation tolerances for rod position and blade opening. The 4 mm and 5 mm figures are safety criteria.

What maintenance gap should a switch hold?

Chinese maintenance practice uses 0.5 mm at a pulling point centre and 1.0 mm between points. Project standards govern.

Does the rule apply to movable-point crossings?

The standard sets both criteria for switch blades against stock rails. Movable-point applications follow their own drawing and governing standard.

Who sets the final acceptance limits?

The project drawing and governing railway standard. The criteria are explained here; the project document governs.

Related Reading and Products

The rule belongs to the switch assembly as a whole: the blades it measures, the rods that set the gap, and the names used for each in different standards. Each has its own page or guide on this site.

Inquiry

Send the turnout drawing with the locking-point positions marked, the rail section and the governing standard. Request a quotation with the drawing attached.

Related Products

We have recommended some of our Related products to you. I hope you will be interested.

Quick Inquiry