QU70 / QU80 / QU100 / QU120 crane rails with profile dimensions and theoretical mass aligned to YB/T 5055-2025
DIN 536-1:1991-09 Form A sections from A45 to A150, with profile data identified by source
ASTM A759-21 special-design carbon-steel crane rails in the 104-175 lb/yd nominal-weight range
QU nominal masses: 52.77 / 64.41 / 89.05 / 118.50 kg/m to YB/T 5055-2025 Table 3
Edition-aware specification: YB/T 5055-2025 published 2025-08-19 and effective 2026-03-01, replacing YB/T 5055-2014
Steel grade, delivery condition and inspection requirements confirmed against the applicable standard and order
Rail, pad, sole plate, fixing and girder treated as one load path with a defined supply boundary
Bolted, welded and insulated joints, with electrical isolation arranged to the track-circuit design
Current drawing reference 23G525 for applicable steel crane-girder rail connections, expansion joints and stops
Cut length, drilling, end preparation and packing confirmed against the approved drawing and order
Crane rails are supplied as QU70, QU80, QU100 and QU120 rolled sections, DIN 536-1 form A and ASTM A759 profiles. The QU number is nominal head width, not mass. Mass figures are edition-dependent: the current standard table and older supplier catalogues give different values for the same four sections. State the edition on every quote so that two offers can be compared.
A crane runway transfers each wheel reaction through the rail into the supporting girder and its connections. The contact patch is local, and the rail head must accommodate the wheel tread while the section and support resist vertical bending and lateral actions. Unlike a conventional railway track, the runway is commonly supported by a relatively stiff steel or concrete structure rather than sleepers and ballast. The design therefore has to consider the wheel reactions, rail profile, fastening arrangement and girder as one system. The load path is different from that of a mainline railway rail, so the two profile families should not be treated as interchangeable.

The profile geometry reflects that load path. Head width has to suit the wheel tread and allow for the specified alignment tolerance. The web and overall section properties contribute to the rail’s bending resistance between effective support points. The foot provides the bearing and fixing interface with the pad, sole plate or other support detail. These dimensions work together; a change in one dimension can affect section properties as well as clip and support compatibility. Runway alignment and support condition must therefore be checked alongside rail condition.
Duty classification should be taken from the applicable crane or mechanism standard and the project design basis. ISO 4301-1:2016 classifies cranes and mechanisms using service conditions that include total working cycles, load spectrum and average displacement. A class assigned to a hoisting or travelling mechanism should not automatically be treated as the classification of the complete crane or as a direct rail-size recommendation. Start-stop frequency, wheel diameter, tread width, skew forces and operating spectrum all matter, but the crane supplier and runway designer must provide the design inputs.
On a port or steel-mill runway, inspection may reveal flattened or mushroomed rail heads, local wear, corrugation or polished marks associated with skew and alignment. These are symptoms that need to be assessed with the wheel tread, wheel reactions, rail material, fastening condition and girder alignment. The maintenance plan should define inspection intervals and replacement limits from the project duty and measured condition; there is no universal replacement interval for every crane rail.
Enquiry wording varies with the project market. Crane rail, crane runway rail, gantry rail and overhead crane rail are common terms for this product family. QU designations identify the Chinese QU70 to QU120 profile series; DIN A designations identify Form A crane-rail profiles under DIN 536-1. ASTM A759-21 covers special-design carbon-steel crane rails within its stated nominal-weight range. CR and MRS labels also occur in supplier catalogues, but a designation alone does not establish compliance with ASTM A759-21 or another standard. Ask for the profile drawing and the governing specification.

Three nearby words cause expensive mistakes. A rail clip or rail clamp holds the rail foot down. It is not a rail. A rail anchor is an anti-creep device on railway track. A fishplate or joint bar connects two rail ends.The bar itself, its hole pattern and its joint form are set out on the crane rail fishplate page. When an enquiry lists only "crane rails and accessories", ask which of these are in scope before the quantity is fixed.
For consistency, QU designations are written without a space, as in QU100, and DIN A-series designations as A100. Mass is given in kg/m. In the tables on this page, the dimensions are shown in this order: head width, height, base width and web thickness, all in millimetres. Tensile strength, where specified, is stated in N/mm². Keeping the sequence and units consistent makes it easier to check the data against a mill drawing.
Dimensions on this page are published standard and catalogue values. The applicable standard text and the approved project drawing govern the order; a value printed in a supplier table is a starting point for a drawing check, not an acceptance criterion. Which inspection documents apply to a given lot is confirmed when the order is placed.
Three profile families appear frequently in international enquiries. The QU series to YB/T 5055-2025 covers QU70, QU80, QU100 and QU120 for crane bridge and trolley tracks. DIN 536-1:1991-09 covers Form A foot-flange crane rails, with profiles such as A45 to A150 appearing in manufacturer catalogues. ASTM A759-21 covers special-design carbon-steel crane rails with nominal weights from 104 to 175 lb/yd. The standards define different product scopes and acceptance bases; a profile from one family should not be substituted for another on the basis of mass alone.

Other profile names may appear in regional or supplier catalogues, including JIS-related CR designations, MRS sections, ASCE sections and UIC50 / UIC54 / UIC60 railway rails. Treat these as separate profile references, not as interchangeable equivalents. A railway rail may be considered for a light industrial track only when the crane wheel reactions, tread geometry, section properties, fastening system and supporting structure have been checked by the responsible designer. A similar nominal mass does not establish suitability.
Availability matters as much as geometry. Special crane sections are not rolled every week, and a mill may prioritise common railway sections. If the specified profile cannot be delivered in the required length or grade, the substitution has to be checked against wheel load, head width, web capacity and steel grade before it is offered. An alternative section with a wider head and a thinner web is not automatically equivalent.
For QU sections, YB/T 5055-2025 specifies a general standard length range of 6 m to 12 m; other lengths may be supplied when agreed between the purchaser and supplier and recorded in the contract. DIN A-series and ASTM A759-21 supply lengths depend on the mill, section and order. Confirm the actual rolling length, end preparation, transport limit and site installation sequence together; catalogue availability is not a project delivery commitment.
Within the QU series, the numeral corresponds to the nominal head width in millimetres: QU70 has a 70 mm head, QU100 a 100 mm head, and so on. The published profile dimensions are shown below. The nominal masses are taken from Table 3 of YB/T 5055-2025; the applicable standard and approved drawing govern dimensional tolerances and acceptance.The grade behind these QU sections is explained in the U71Mn crane rail steel grade guide.

Section | Head width (mm) | Height (mm) | Base width (mm) | Web (mm) | Nominal mass (kg/m) | Grade quoted |
QU70 | 70 | 120 | 120 | 28 | 52.77 | U71Mn |
QU80 | 80 | 130 | 130 | 32 | 64.41 | U71Mn |
QU100 | 100 | 150 | 150 | 38 | 89.05 | U71Mn |
QU120 | 120 | 170 | 170 | 44 | 118.50 | U71Mn |
YB/T 5055-2025 Table 3 gives theoretical masses of 52.77 kg/m for QU70, 64.41 kg/m for QU80, 89.05 kg/m for QU100 and 118.50 kg/m for QU120. Other supplier catalogues may show different rounded figures. Where the order specifies YB/T 5055-2025, use the standard’s theoretical-mass values and state any agreed actual-weight basis explicitly in the contract. Do not explain a catalogue difference by assumed density or fillet-radius changes unless the source drawing confirms it.
U71Mn is a commonly quoted grade for QU rails, but it is not the only grade option discussed in the current Chinese standard. The 2025 edition changes the U71Mn chemistry requirements and adds grades including U68CuCr, U22SiMn and U20Mn. U75V also appears in some supplier catalogues; its use for a specific crane-rail profile must be confirmed against the applicable standard, mill capability and project order. Specify the grade, delivery condition and required inspection basis rather than assuming one grade applies to every QU section.
A-series sections sit lower and wider than QU sections of similar mass. A100 is 95 mm high with a 200 mm base, while QU100 is 150 mm high with a 150 mm base. That difference changes the bending stiffness, the sole-plate width and the clip geometry, so the two cannot be swapped on an existing girder without rechecking the whole support arrangement.

Section | Head width (mm) | Height (mm) | Base width (mm) | Web (mm) | Nominal mass (kg/m) | Grade quoted |
A45 | 45 | 55 | 125 | 24 | 22.10 | 50Mn |
A55 | 55 | 65 | 150 | 31 | 31.80 | 50Mn |
A65 | 65 | 75 | 175 | 38 | 43.10 | U71Mn |
A75 | 75 | 85 | 200 | 45 | 56.20 | U71Mn |
A100 | 100 | 95 | 200 | 60 | 74.30 | U71Mn |
A120 | 120 | 105 | 220 | 72 | 100.00 | U71Mn |
A150 | 150 | 150 | 220 | 80 | 150.30 | U71Mn |
In the DIN 536-1 Form A dimension table reproduced here, the A designation corresponds to the nominal head width shown in the profile data: for example, A100 has a 100 mm head and a 95 mm overall height. Always confirm the actual section against the standard drawing and mill data sheet. The table values are published profile data; dimensional tolerances and acceptance are governed by the applicable edition of DIN 536-1 and the project specification, not by a secondary catalogue table.
Some supplier catalogues list 50Mn for A45 and A55 and U71Mn for larger A sections. These are catalogue supply descriptions, not a universal grade assignment based only on the A designation.The American family works differently:ASTM A759 designations read from CR104 to CR175 are numbered by weight per yard rather than head width, and the standard names no grade at all.The required steel grade, chemical composition, delivery condition, hardness or other mechanical properties must be stated against the governing standard and the project order.
Edition numbers matter because they define the applicable product and acceptance requirements. YB/T 5055-2025, Crane rails, was published on 2025-08-19 and took effect on 2026-03-01, replacing YB/T 5055-2014. The National Standards Information Public Service Platform lists the 2025 edition as current. Its scope covers ordering information, dimensions, shape, mass, technical requirements, test methods, inspection rules, packing, marking and the quality document for QU70 to QU120 crane rails used on bridge and trolley tracks. The standard gives a general standard length range of 6 m to 12 m and permits other lengths by agreement. Write the full standard number and year on the enquiry.

ASTM A759-21 covers special-design carbon-steel crane rails for crane runway use, with nominal weights from 104 to 175 lb/yd. ASTM states that inch-pound values are the standard values; the SI figures in parentheses are mathematical conversions for information and are not the standard basis. DIN 536-1:1991-09 is listed as CURRENT by DIN Media and covers dimensions, sectional properties and steel grades for Form A foot-flange crane rails. These documents define different section families and acceptance bases. None should be substituted for another without an engineering review and purchaser approval.
The current Chinese standard-design drawing for applicable rail connections and stops on solid-web steel crane girders is 23G525, which took effect on 2024-06-01 and replaced 05G525. The drawing set includes rail fixing details, rail expansion-joint connections and stops for QU70, QU80, QU100 and QU120 arrangements. Use the relevant current detail for the actual rail profile and girder configuration. Do not carry over dimension chains from the withdrawn 05G525 without checking the corresponding 23G525 drawing and the project design.
A project may therefore name more than one governing document: a rail-product standard for the section and material, a current structural drawing for the rail-to-girder connection, and a site welding or inspection specification.Which document governs each of these sections is set out in the crane rail standards comparison. List each document with its edition or drawing number in the enquiry. A description such as “crane rail to standard” is not enough to align the rail, fastening and girder interfaces.
Grade selection depends on the rail standard, wheel reactions, duty spectrum, expected wear and the project environment. U71Mn is commonly listed for QU rails, while other grades are available under the current YB/T 5055-2025 framework subject to the specified profile and order. U75V and 50Mn appear in some supplier catalogues, including for certain QU or DIN A-series offerings, but catalogue listings do not establish a universal grade mapping. North American orders should follow the material requirements of the specified ASTM product standard. State the grade and required properties explicitly.

A single generic tensile-strength range is not a reliable specification for all crane-rail grades or profile families. Mechanical properties depend on the named grade, product standard, delivery condition and any agreed heat treatment. YB/T 5055-2025 contains grade-specific chemistry and tensile-property requirements; DIN and ASTM orders have their own material requirements. Use the applicable standard table and mill certificate for the selected grade, and do not copy a strength figure from a general supplier guide into a purchase specification without confirming its basis.
Head hardening, full-length heat treatment, weathering-steel options and supplementary examinations must be specified only where the selected standard and project design call for them. YB/T 5055-2025 allows certain additional checks, such as non-metallic inclusion examination or full-length ultrasonic testing, to be agreed between purchaser and supplier as special requirements. For any hardness profile, Charpy test or ultrasonic examination, name the test method, sampling extent and acceptance limits in the enquiry. The inspection documents applicable to a lot are confirmed in the order.
The selected grade must satisfy the project’s material requirements, wheel reactions, duty spectrum and wear allowance. Material selection cannot compensate for an inadequate rail seat, unsuitable fastening or poorly aligned runway girder; the complete support arrangement must be checked as part of the design.
On a port gantry, each crane wheel transfers its reaction through a local contact patch on the rail head. Crane skew and other transverse actions can also create lateral forces at the rail and fastening. A conventional railway rail is designed for a different system: wheelset loads are transferred through the rail to sleepers, ballast and formation, while gauge and flange interaction are controlled by the track geometry. The two rail families therefore have different section proportions and different support interfaces.

The dimensions illustrate the difference. A 60E1 (UIC60) railway rail is 172 mm high, has a 150 mm base, a 72 mm head, a 16.5 mm web and a nominal mass of 60.21 kg/m. QU100 is 150 mm high, has a 150 mm base, a 100 mm head, a 38 mm web and a theoretical mass of 89.05 kg/m to YB/T 5055-2025. The matching base widths do not make the sections interchangeable: the head and web geometry, section properties and fastening interfaces are substantially different. Any proposed substitution needs a project-specific calculation and approval.
UIC54 and UIC50 are railway-rail profiles, not direct alternatives to QU or DIN crane rails. They may be considered for a light industrial track only where the wheel reactions, wheel tread, support spacing, rail section properties and fixing arrangement have been checked for the actual duty. A substitution on a heavy runway must be justified by calculation, not by availability or nominal mass. Sourcing railway steel rails is a separate enquiry from sourcing a crane runway section; the profile drawing and governing standard must be stated.
A proposed UIC60 substitute must be checked against the maximum vertical wheel reaction, wheel tread and flange geometry, rail section properties, lateral actions, support spacing and the complete fixing arrangement. The girder, pads, sole plates and clips may also need redesign. Similar base width alone is not sufficient evidence of suitability.
Selection starts with the maximum vertical reaction at an individual wheel, not with the crane’s rated lifting capacity alone. The reaction depends on the crane dead weight, lifted load, trolley position, wheel arrangement and applicable dynamic factors. Lateral forces from skew, acceleration or other operating effects should be assessed separately in accordance with the project design basis. Request the wheel-load schedule or calculation used for the runway design.

The profile check should cover at least five areas. First, head width and head geometry must suit the wheel tread and the permitted alignment movement. Second, the rail section properties must resist the bending and contact actions for the actual support condition; web thickness alone is not a complete check. Third, the specified grade and delivery condition must meet the duty and wear requirements. Fourth, the pad, sole plate, clips or welded fixing and runway girder must provide the designed support stiffness and load transfer. Finally, the environment may require corrosion protection, drainage provisions or special maintenance controls. Pad thickness and hardness are project-specific and should not be copied from a generic catalogue as universal values.
The fastening arrangement is selected from the runway girder design, rail-seat detail, adjustment requirements, thermal movement, installation method and maintenance strategy. Continuous or discrete support, welded or bolted fixing and the spacing of clips or sole plates must follow the approved design. A duty classification by itself does not prescribe one fixing method, and the rail section should be checked using the support conditions actually specified.
There is no reliable one-line table that maps a wheel load directly to a QU or A-series designation. Two runways with similar wheel reactions may require different sections because their wheel geometry, support spacing, girder stiffness, lateral actions and duty spectra differ. Send the wheel-load schedule, girder spacing, crane type, operating classification and support drawing so the profile can be checked against the actual design.
The load path crosses a supply boundary at the rail foot. Wheel load goes into the rail head, through the web, out through the foot, into the rail pad and sole plate, then into the girder flange and the building structure. Everything above that line is rail section, grade and length. Everything below it is pad, plate, fixing and weld. Keeping the two halves on the same enquiry prevents the classic mismatch: a QU100 rail delivered with clips drawn for a different foot width.

The current drawing reference for applicable steel crane-girder rail fixing details is 23G525, which superseded 05G525 on 2024-06-01. It contains details for rail fixing, expansion-joint connections and stops, including arrangements for QU70, QU80, QU100 and QU120. Select the applicable detail from the current drawing set and check it against the actual rail foot, girder flange and project design. This page does not repeat the dimension chain from the withdrawn drawing: those dimensions belong to the fixing assembly and its support, not to the rail profile.
The fixing side is covered separately in the crane rail clips page, which deals with side load, bolt grade, tightening torque, clip pitch and weld details. Bolts, nuts and washers come from the railway track bolts range, and their grade, dimensions and thread tolerance have to match the clip assembly. Splitting the order across suppliers is workable, but only if one approved drawing governs all components.
A practical consequence: an existing runway that is being re-railed rarely needs a new rail type. It needs the same foot geometry, a check on head wear and a fixing layout that still fits the girder flange. Changing the section to gain a wider head usually means changing the pads, the plates and the fixings too.
Joints are bolted, welded or insulated. Bolted fishplate joints are easy to inspect and to replace, and they remain common on crane runways where thermal movement and maintenance access matter. Welded joints give a continuous running surface and are used where impact at the gap has to be removed; they need a qualified procedure and inspection on site. Expansion joints sit where the structure demands movement, not where the rail length happens to end.
Some crane runways use track circuits or other electrical detection and positioning systems. Where a track-circuit boundary is designed using an insulated rail joint, the joint location and the arrangement of insulation on one or both rails must follow the signalling or electrical design; this is not a universal two-rail rule for every system. The rail joint, gauge restraints, clips, sole plates and supporting steelwork must be checked so that no unintended conductive path bypasses the specified insulating boundary. The exact arrangement depends on the circuit topology and the project requirements.
Typical joint solutions include a composite insulated fishplate for certain bolted assemblies, and a glued insulated rail joint supplied as a bonded unit. The available constructions and their suitability depend on the rail section, hole pattern, wheel load, support arrangement, maintenance access and the electrical design. Confirm whether the selected product is approved for the crane runway application, and state the required insulation performance and test method in the enquiry. The position of an insulated joint relative to a stop, switch or expansion joint is determined by the project layout, not by the rail supplier alone.
Crane rail joints also need mechanical continuity. A joint gap that is too wide batters the rail ends; one that is too tight leaves no room for thermal movement. How the plate is matched to the rail end is covered in the fishplate selection guide.The joint bar has to match the rail foot and hole pattern of the specific section - a bar drilled for QU80 will not fit QU100.
Mushrooming or metal flow at the rail head is an indication that the contact and support conditions need to be checked; it is not a root-cause diagnosis by itself. Review the wheel reaction, wheel tread, alignment, rail material, rail-seat support and fastening condition. Corrugation or ripples may point to dynamic interaction; loose clips or lateral movement may point to the fixing or support arrangement. Record the location and pattern of each defect before deciding whether the rail itself needs replacement.
Installation tolerances are set by the applicable standard, approved drawings and project specification. Gauge or track spacing, level, straightness, alignment and joint gap must be measured against those documents. A supplier catalogue is not the acceptance basis. Where sole plates and grout are used, the support must be installed to provide the bearing condition assumed in the design; local voids or uneven seating can create concentrated reactions. Complete an alignment survey before handover and retain the measurement record.
A scheduled walk covers four things. Check the rail head, the joint gaps and bolt tightness, the clips and pads, and any polished marks on one side of the head that point to gantry skew. Record the position of a defect, not just its size. A wear pattern that repeats every few metres usually has a structural cause upstream.
Rail inspection and replacement should follow the project maintenance plan, measured wear, defect limits and the operating duty. A universal replacement interval cannot be inferred from the profile designation alone. For special sections, it is sensible to agree spare lengths and matching joint or fixing components during commissioning because mill availability and rolling schedules vary.
Cut length, drilling and end preparation are confirmed against the installation drawing. YB/T 5055-2025 gives a general standard length range of 6 m to 12 m for QU sections, with other lengths by agreement. DIN A-series and ASTM A759-21 supply lengths depend on the mill, section and order rather than one universal length rule. Curved lengths, bolt holes, bevels and special machining must be quoted to the approved drawing, with the hole pattern checked against the joint bar and fixing layout.
Non-standard sections or special machining should be supplied only against an approved engineering drawing. Changes to rail height, head width, web thickness or base width affect section properties and connection interfaces and therefore require design verification and purchaser approval; they are not routine dimensional adjustments. A project that also needs switch work may specify railway turnouts and an integral cast slide baseplate for turnouts against the same layout package. Grade, heat treatment and supplementary inspection requirements are confirmed against the governing standard and order.
Packing and commercial terms are project-specific: MOQ, bundle weight, anti-corrosion protection for sea freight, marking, destination port and the documents required at customs. State the destination and the required packing in the first message. Which inspection documents apply to a given lot is confirmed when the order is placed, together with the marking, packing and customs documents required for the destination.
Put the whole package on one enquiry: rail section and edition, grade, length and drilling, joint type, pad and fixing arrangement, packing and destination. A quote built from a single part number usually comes back missing half of that list.
YB/T 5055-2025 is the current edition. It was published on 2025-08-19 and took effect on 2026-03-01, replacing YB/T 5055-2014. For QU sections, the standard gives a general standard length range of 6 m to 12 m, with other lengths by agreement. State the full standard number and year on the order.
Within the QU series, the number corresponds to the nominal head width in millimetres: QU70, QU80, QU100 and QU120 have nominal head widths of 70, 80, 100 and 120 mm respectively. Confirm the full section dimensions against the applicable standard drawing and approved profile data.
Not without an engineering check. Both profiles have a 150 mm base, but 60E1 (UIC60) has a 16.5 mm web and a 72 mm head, while QU100 has a 38 mm web and a 100 mm head. Their section properties and wheel-contact geometry differ, and the complete support and fixing arrangement must be recalculated and approved before any substitution.
Both scopes are possible. The rail is one line on the order; pads, sole plates, clips, bolts and joint bars are separate lines. State the boundary in the enquiry so the clip geometry is checked against the rail foot.
Yes. Cut length, end preparation, bolt holes and curved lengths are quoted against the approved drawing. The hole pattern has to match the joint bar and the fixing layout.
Specify the grade required by the governing product standard and project design. U71Mn is commonly quoted for QU rails; YB/T 5055-2025 also introduces additional grade options, including U68CuCr, U22SiMn and U20Mn. U75V and 50Mn appear in some supplier catalogues, but their use must be confirmed for the selected profile and order. State the required delivery condition, mechanical properties and inspection basis rather than relying on a generic catalogue grade list.
An insulated rail joint is needed only where the electrical detection or control design requires an insulated boundary. Its position and whether one or both rails are insulated depend on the circuit topology and project design. Check the joint, gauge restraints, clips, sole plates and other metalwork for unintended conductive bypasses across the required boundary.
The section is selected from the maximum vertical wheel reaction, wheel diameter and tread width, operating duty and load spectrum, lateral actions, support spacing, girder stiffness and fastening arrangement. There is no reliable one-line conversion from wheel load to profile number; the wheel-load schedule and support drawing are essential.
The documents depend on the governing product standard, project specification and purchase order. YB/T 5055-2025 requires the applicable quality document and defines inspection requirements for QU rails; supplementary checks such as full-length ultrasonic testing must be agreed where required. State the test methods, sampling extent and acceptance limits in the enquiry. Do not assume that a particular report or third-party inspection is included unless it is confirmed in the order.
Both are confirmed per order. Rolling availability, length, total tonnage, packing and destination port all affect the schedule; state them in the first message.
Send the rail section and standard edition, wheel-load schedule, crane type and duty classification, girder spacing, required length and drilling, joint and insulation arrangement, and destination port. A layout drawing in PDF or DWG makes the drawing check more efficient. contact us with these details so the quotation can be based on the actual profile and support requirements rather than on a designation alone.