Crane rail fishplate specified by rail section, hole pattern and bolt set
Four-hole and six-hole drilling explained
Hole diameter, pitch and end distance to the joint drawing
Bolted, 45-degree scarf and welded joints compared
23G525 current rail connection details; YB/T 5055-2025 rail sections
Catalogue values labelled, never presented as ATK test results
Fishplate, joint bar, splice bar and compromise plate distinguished
What fails first on a crane runway
Inspection checklist for the enquiry
Enquiries for crane runway joints rarely name the same part twice. One message asks for fishplates, the next for joint bars, a third for splice bars or angle bars, and a fourth simply says "the plates with the holes". They usually mean the same component. The confusion is not harmless: it is how a QU80 drilling pattern gets quoted against a QU100 rail.
A fishplate is a mechanical splice. Two bars sit either side of the rail web, bolts pass through the web, and the assembly holds the two rail ends level and in line while allowing a controlled gap for thermal movement. That is all it does. It does not make a weak runway stiff, and it does not turn two badly aligned rail ends into a smooth running surface.

A batch of crane rail fishplates with round and slotted bolt holes, inspected before packing.
Fishplate is the common term in Europe and Asia. Joint bar and splice bar are the North American equivalents. Angle bar survives in older catalogues, and "rail clamp" sometimes gets misapplied to this part by buyers who have been reading about crane rail clips instead. All of the first four describe the same bolted splice bar. A rail clamp does not.
A compromise (or transition) fishplate is machined with two half profiles to join rails of different sections or different head wear. A joggled plate is a repair arrangement for a cracked or broken joint, usually temporary. Neither word tells you anything about electrical isolation. Where a track-circuit boundary is involved, the enquiry has to say so explicitly; the insulated rail joints page covers where those are required.
The rail fastenings category collects the related parts, but this article stays with the plain bolted splice: how to specify one so that it fits, tightens and survives on a crane runway.The plain railway version of that part, on line rail rather than runway rail, is specified under railway fishplates.
Most enquiries arrive with the plate dimensions already fixed and the rail described in a word or two. That order is usually the wrong way round, because the rail settles most of the answers.
Crane rails are not railway rails with a different name. QU70 to QU120 under YB/T 5055-2025, the DIN 536 A-series, and the Russian KP family all use head width in the designation, but their height, base width and web thickness differ. A100 and QU100 both have a 100 mm head; the A100 is 95 mm high with a 200 mm base, the QU100 is 150 mm high with a 150 mm base. A bar machined for one will not seat on the other. The QU designation article explains what the number does and does not tell you, and the crane rail sections page carries the full profile table.
None of that is answerable from a catalogue, so the conversation usually has to go back a step:
Input | Why it decides the plate |
Rail designation and governing standard | Sets head, web, base and the drilling datum |
Standard edition on the project drawing | Tolerances and grade assignment follow the named edition |
Rail-end drilling, if the rail is already on site | The plate must match the holes that exist, not a catalogue pattern |
Existing runway or new build | Re-railing usually keeps the same foot geometry; a new section changes pads and fixings too |
Drawing number for the joint detail | The only document that resolves a conflict between catalogue values |
Published catalogues list crane rail bars against QU70, QU80, QU100 and QU120 in a standard table of length, hole diameter and bolt size, and the rows look authoritative because they repeat from site to site. Those are catalogue figures from supplier tables, not ATK test results for a particular batch; they help frame an enquiry and they are not an acceptance standard. The approved joint drawing governs. The same table appears further down, together with what it leaves out.

A rail standard tells you what the rail is. It does not tell you what the bar is, and most specification arguments start when the two get mixed. Buyers ask which standard the fishplate should meet; for crane rail there is no fishplate standard inside the rail series, which is why the joint drawing carries the specification.
Standard | What it governs | What it does not cover |
YB/T 5055-2025 (in force 1 March 2026, replaces the 2014 edition) | QU70 to QU120 crane rails: ordering information, dimensions, shape, weight, technical requirements, test methods, inspection rules, packing and marking | Bar length, hole pattern, bolt grade, joint method |
ASTM A759-21 | Carbon steel crane rails of special designs, 104 to 175 lb/yd (51.6 to 86.8 kg/m) | Anything at the joint |
DIN 536-1:1991-09 | Form A crane rail with foot flange: dimensions, sectional properties, tolerances and steel grades; the Form F sections are a separate document | Bar drilling, bolt size |
GOST 4121 | Crane rails of the KP series | Bar drilling, bolt size |
23G525 (in force 1 June 2024, replaces 05G525) | Chinese standard details for the rail-to-girder connection, rail splices and expansion joints on steel crane girders | It is not an international fishplate standard |
ISO 4301-1 | Duty classification of the crane as a whole, which sets the cycle count the joint sees | Any rail or bar dimension |
EN 1993-6 | Design of crane supporting structures | The joint detail |
Project drawing and technical agreement | The bar itself: hole pattern, material, finish, tolerances and acceptance | Nothing above overrides it |
In practice, a quotation that names only the rail standard has not specified a bar at all, and a bar quoted "to ASTM" without a drawing has no defined drilling. Where the project names a standard detail drawing, that drawing and the technical agreement sit above everything on this page.
Buyers often ask which fishplate to buy when the real question is whether the runway should have bolted joints at all.
A plain butt joint with a fishplate is the workhorse for light and medium duty. It is quick to install, easy to dismantle, and tolerant of later changes to the track layout. It also leaves a gap, and every wheel passing that gap delivers an impact. On high-cycle or heavy-duty runways that impact is what drives rail-end batter, bolt loosening and fatigue cracks around the holes.The crane rail joint problems guide works through those symptoms one by one, from the first bump to a cracked weld.
A 45-degree scarf joint reduces the step the wheel feels, because the two rail ends overlap in plan rather than meeting square. It still needs a fishplate and a drilling pattern, but the pattern is longer and the rail ends have to be machined accordingly. Welded joints remove the gap altogether and suit demanding continuous runways, but they bring a qualified welding procedure, preheat, post-weld treatment and inspection. Welding is not simply a way of avoiding fishplates; it is a different construction with its own approval basis.
Chinese crane runway practice sets those details out in the current standard design drawing 23G525, Crane Rail Connections and Stops for steel crane girders, which took effect on 2024-06-01 and replaced 05G525; it covers rail splices and the splice arrangements at rail expansion joints. Supplier pages still quoting 05G525 are citing the superseded edition. Settle the joint method with the runway designer before the plate is specified. Ordering a heavier bar to cure impact on a plain butt joint usually treats the symptom. Where the project already uses welded rail, fishplates remain at buffer rails, expansion arrangements, insulated boundaries and temporary repairs — not along the whole runway.
Four-hole bars are shorter, lighter and quicker to fit. Six-hole bars are longer, stiffer and spread the clamping load across more bolts. Published comparisons consistently put a six-hole joint ahead on clamping effect, with most of the benefit showing up as vertical stiffness and resistance to the joint "dipping" under repeated wheel loads.
Four-hole bar | Six-hole bar | |
Typical length | Shorter, commonly around 24 in / 600–630 mm | Longer, commonly around 36 in / 800–900 mm |
Load paths | Fewer, more load on the bolts nearest the gap | More, load shared more evenly |
Stiffness | Adequate on light and medium duty | Better where wheel loads and cycling are high |
What it needs | Correct rail-end drilling | Correct drilling and enough clear web either side of the joint |
Typical failure if underspecified | Hole elongation and bolt fatigue | Usually installation error, not plate strength |
Neither bar is the better product in the abstract. A six-hole bar on a rail drilled for four holes is scrap. Equally, a six-hole bar cannot be fitted where a clip, a girder splice or a guide roller leaves no room for the outer bolts. Check the joint against the actual clip layout before specifying it — the clip layout article shows how pitch and joint position interact.

Four-hole and six-hole drilling patterns. Schematic only - not to scale; drill and inspect to the approved joint drawing.
"M24, six holes" is not a specification. Neither is a photograph with a tape measure laid alongside it.
A hole pattern fixes four things at once: hole diameter, the pitch between adjacent holes, the end distance from the bar end to the first hole, and the position of the holes relative to the rail centreline. Catalogue tables often give spacing as a pair of figures, for example 100/120 or 105/125. The pair refers to two different spacings within the same pattern; which is which is defined by the drilling drawing, not by the table. Treat the pair as a prompt to ask, not as a dimension to copy.
A pitch that is too large reduces the contact length and throws extra load on the bolts nearest the gap. Too small a pitch removes material between holes and invites cracking there. An oversized hole is worse than either: the bolt can move, the bar works against the rail web, and the hole elongates within months. Published Chinese guidance treats a growing hole-spacing deviation as the point where connection strength starts to fall, and calls for centre-to-centre measurement with a vernier caliper across at least three adjacent pairs. There is no universal figure for when it counts as out; the tolerance on the joint drawing is what an inspector measures against.

Checking bolt hole diameter with a vernier caliper during incoming inspection.

Measuring the distance between two holes. The reading belongs in the inspection record, not in the product description.

Slotted holes are checked across the width as well as along the bar.

Overall length is easy to check and often the first thing a buyer asks for. It is also the least informative.
Ask for the drilling drawing with the quotation. If the supplier can only provide a length and a hole count, the pattern has not been defined. Round holes and slotted holes in the same bar are common on crane rail joints; they serve different assembly needs and must be identified by position, not guessed from a photograph. When an enquiry reaches us with a photograph and no drawing, the first reply is nearly always a request for the pitch, the end distance and the hole diameter, because those three cannot be scaled off a picture with any confidence.
Plain carbon and medium-carbon steels dominate this part. Published supplier material lists run from Q235 through Q255 to 45# and 55#, with higher-strength or alloy options for heavy cyclic duty. A higher grade is not automatically better: the plate, the bolt grade and the specified torque have to be designed as one set. A hard bar on a soft bolt simply moves the failure to the fastener.
The bolt set is part of the joint, not an accessory. Grade 8.8 is commonly quoted in crane rail joint tables; the exact grade, washer arrangement and locking method belong on the drawing. Mixing bolts from different batches, reusing stretched bolts, or fitting a bar without its spring washers are all ways to lose preload in the first months. The railway track bolts pages cover the fastener side of the same assembly.
Surface treatment follows the site. Oiled or black finish is normal for indoor workshops. Galvanising or a painted system is worth specifying for coastal, mining or wash-down environments, where corrosion pits become the crack initiation sites. Do not choose the finish from a price list; choose it from the environment the joint will actually sit in.
The fishing surface is the machined contact between the bar and the rail web. It carries the load. A bar that looks correct on a pallet can still fail this check.
Industry references describe checking the gap between bar and web with a feeler gauge, with tight limits on straight track and slightly wider ones on curves, and treating a persistent gap as a load concentration point rather than a cosmetic defect. The practical sequence is simple: clean both faces, offer the bar up, bolt it hand-tight, then check the contact before applying final torque. Rust, mill scale and burrs on the rail end reduce friction and let the joint work under load.
A bar that has been bent in transit, a hole that is out of perpendicular, and a web that was never machined flat all produce the same symptom — the joint feels tight but the bearing is uneven. Grinding the rail ends and cleaning the fishing surfaces before assembly takes minutes. Re-doing a joint after the runway is in service does not.
On a replacement job the old bar is the best record of what the original drawing meant. Keep it, lay a rule across the holes and photograph both faces, and note which way round it was fitted: a bar that has carried wheels for ten years shows a witness mark where the web sat, and that mark is often the clearest statement of the contact geometry you are trying to reproduce.
A bolted joint needs a gap. The rails expand in heat and contract in cold; the gap gives that movement somewhere to go. Published installation guidance quotes different normal splice gaps — 1–3 mm in some crane runway references, 2–4 mm with fishplates in others, and wider allowances where the temperature range is large. The spread is the point: the figure is calculated from the rail length, the temperature at installation and the local seasonal range, not copied from a catalogue.
Steel rail expands by roughly 11.5 × 10⁻⁶ per °C. A 12.5 m rail length can therefore change by close to 6 mm across a 40 °C swing. Close the joints tight on a cold morning and the runway has nowhere to go in summer. Leave them too wide and every wheel hammers the rail ends. The fixed end of the runway, the direction of expansion and any dedicated expansion joints belong in the design, not in the site foreman's judgement on the day.

The gap is only one of the alignment questions at a joint:
Check | Why it matters |
Vertical step and lateral offset at the joint | Published crane runway limits are around 1 mm; a step of half a millimetre is audible and wears wheels |
Joints staggered between the two rails | Joints opposite each other deliver a simultaneous impact to both sides of the crane |
Joint kept away from wheel dwell points | Loading bays, cab parking positions and fixed stops concentrate traffic on one joint |
Joint position and fastening layout interact. A joint that lands on top of a clip station, a girder splice or a guide roller clearance cannot be assembled correctly. Check it against the clip layout and the crane rail clips arrangement before the rail is delivered.
Two runways can use the same rail and the same plate design and still need different joints, because the joint works harder on one than on the other.
Condition | Why it changes the joint | What to state in the enquiry |
Duty classification (ISO 4301-1) | The class is a cycle count, not a quality grade; more cycles means more load reversals at the hole edges | Duty class, or cycles per year |
Wheel load and rail section | Sets the bearing and bending stress the bar carries across the gap | Maximum wheel load and rail designation |
Indoor workshop | Temperature is stable and the rail is oiled, so a plain finish usually survives | Indoor duty, and the finish already on the rail |
Outdoor runway | The joint gap and the expansion provision take over; a wide seasonal range can double the gap needed | Installation temperature and the annual range |
Coastal or port site | Salt and wash-down pit the bar and the bolt threads, and pits become crack starters | Corrosion category, or the finish required |
Foundry or steel mill | Radiant heat, dust and scale on the fishing surface; scale prevents contact | Ambient conditions and the cleaning regime |
Steel girder or concrete beam | Fixing type and pad differ, and a joint that lands on a stiffener or a girder splice cannot be assembled | Girder type and the fixing layout |
Electrified track or track circuit | An insulated joint is required at the boundary; that is a signalling requirement, not a conductivity question | Whether insulation is needed, and where |
Existing drilling | A replacement bar has to match the holes already in the rail | Photograph of the rail end plus a measured pitch |
Maintenance access | A joint under an end stop or in a pit will not be re-torqued on schedule | Access constraints on site |
A port crane working three shifts and a warehouse crane working one shift can sit on the same A100 rail and still need different bars.
Chinese supplier catalogues carry a table for QU rail bars that repeats almost word for word from site to site:
Rail | Bar length | Bar width | Bar thickness | Hole dia. | Hole spacing | Bolt |
QU70 | 760 mm | 70 mm | 20 mm | 24 mm | 90 / 105 mm | M24 |
QU80 | 820 mm | 75 mm | 20 mm | 24 mm | 100 / 120 mm | M24 |
QU100 | 950 mm | 80 mm | 22 mm | 26 mm | 105 / 125 mm | M27 |
QU120 | 1,050 mm | 85 mm | 26 mm | 26 mm | 110 / 130 mm | M27 |
The table is useful and it is not a specification. No standard number is quoted against it, several suppliers publish the same rows, and repetition is not evidence. What it leaves out matters more than the missing standard number: the pair of figures in the spacing column refers to two different spacings inside one pattern, and the table says nothing about material, hardness, edge distance or which end of the rail the dimensions are measured from. Use it to frame an enquiry; treat the drawing as the acceptance document. DIN A and ASTM sections have their own catalogue tables in the same format, and the same caveat applies.
A joint that fails early usually failed on the day it was fitted.
Clean the rail ends and both fishing surfaces. Offer up the two bars, insert the correct bolt set, and hand-tighten everything before applying torque. Then tighten from the centre of the joint outwards, in two stages, with a calibrated wrench. Working from one end inwards warps the bar against the web and leaves the middle bolts carrying little load. The torque value comes from the joint design and the bolt grade actually supplied; copying a figure from another clip's or another rail's data sheet is not acceptable.
After tightening, re-check the level and line across the joint, and record the torque. Re-torque at the first planned shutdown and then on the operator's inspection schedule, because preload drops as the joint beds in. Where the site uses locking washers or a specific anti-loosening arrangement, fit the whole set as supplied — a missing spring washer on one bolt changes how the whole bar behaves.

Fishplates being inspected during packing. Dimensional records and the bolt set should travel with the goods.
Ask what documents come with the order: dimensional inspection records, material certificates for the bar and bolt batch, and a certificate of compliance to the named standard. Third-party inspection is a project option, not a default. None of this turns a catalogue value into a type-test result, and a supplier who claims otherwise should be asked for the test record.
A fishplated joint is a moving part. Under every wheel passage the rail ends work against the bars. The usual sequence is predictable.
What is found | What usually caused it | What to do |
Loose bolts | Preload lost as the joint beds in; missing washer; vibration | Re-torque to the specified value, replace stretched or corroded bolts as a matched set |
Elongated holes | Bolts ran loose and the bar worked against the web | Once the hole is oval beyond tolerance, tightening will not recover the joint — replace the bar |
Cracks from a hole edge | Fatigue at the stress concentration, often helped by an oversized or out-of-square hole | Replace the bar and check the drilling pattern before fitting the next one |
Rail-end batter or a dipped joint | Impact at a gap that was too wide, or a step that was never corrected | Investigate the gap and alignment; a new bar alone will not fix it |
Corrosion pitting | Coastal or wash-down environment with a plain finish | Review the specified finish for replacement bars |
Noise or vibration over the joint | Any of the above | Log the location and inspect at the next shutdown, not at the next annual survey |
Published maintenance practice calls for periodic walking checks, a feeler gauge on the joint gap, a hammer tap on bolt heads, and closer inspection after large temperature swings or after any work that disturbs the support. On a heavily worked crane runway, "it looked tight" is not a torque record.
The joint that gives trouble is rarely the one in the middle of a straight run. It sits under the loading bay where the crane parks, or beside the end stop, where every travel crosses it and nobody re-torques it because reaching it needs a permit and a shutdown. When a maintenance log shows the same joint coming back, that is usually where it is.
Most of the back-and-forth on a fishplate order comes from what was left out of the enquiry rather than from the workshop. This is what a supplier needs before a bar can be matched to a runway.
Information to provide | Why it matters |
Rail designation, standard and edition | Fixes the profile and the tolerance basis |
Approved joint drawing or rail-end drilling detail | Defines hole count, diameter, pitch and end distance |
Joint method (butt, scarf, welded) | Determines whether a fishplate is required at all |
Number and position of joints on the runway | Sets quantities and reveals clashes with clips and stops |
Bolt grade, washer set and finish | The plate and fasteners are one assembly |
Installation temperature range and expansion provision | Determines the gap, not the catalogue |
Duty, wheel load and cycling | Drives the four-hole / six-hole and material decision |
Environment (indoor, coastal, mining) | Drives the surface treatment |
Required documents and inspection | Defines what has to be supplied with the batch |
Bars ordered from total rail length alone are the usual first mistake, because that cannot give a count without the joint layout. Assuming the bolts are included comes next, when the quotation said only "fishplates". Ask for the complete joint set: bars, bolts, nuts, washers and any insulating components where the joint is also an electrical boundary.
Yes for a plain bolted splice. The terms differ by region and by catalogue. None of them implies electrical insulation, a compromise profile or a joggled repair arrangement — those have to be stated separately.
No. The head width, height, base and web differ, and so does the drilling pattern. A designation and a standard are the starting point for the check, not a substitute for the joint drawing.
Match the bar to the rail section, the wheel loads and the drilling that exists or is specified. Six-hole bars are longer and stiffer and suit heavier, high-cycle runways; four-hole bars are simpler and adequate on lighter duty. A six-hole bar is useless if the rail ends were drilled for four.
Published supplier tables commonly list 26 mm holes with M27 bolts for QU100, and 24 mm holes with M24 for QU70 and QU80. Those are catalogue values. The bolt size on the approved joint drawing, with the specified grade and washer set, is the one to order.
Only if the quotation says so. The complete assembly includes bars, bolts, nuts and washers, and insulating bushes or an end post where insulation is required. A price for "fishplates" alone is not a price for a joint.
Yes, with a compromise or transition plate machined to fit both profiles. The term says nothing about insulation. Where that transition is also a track-circuit boundary, the insulated rail joints design and the required insulation have to be specified explicitly.
When the joint defines an electrical boundary in the signalling or traction-return design. The construction is different: a composite insulated fishplate uses a non-metallic bar, a glued insulated rail joint bonds the bars to the web. Neither is a standard steel bar with a different coating.
The value is calculated from rail length, installation temperature and the local temperature range. Published guidance quotes 1–3 mm for normal splices in some references and 2–4 mm in others, with additional expansion joints on longer runways. Follow the project design, and keep the vertical step and lateral offset at the joint within the stated tolerance.
Follow the operator's maintenance schedule for the duty class, with a check at the first shutdown after installation and after significant temperature swings or any work that disturbs the support. Heavy-cycle runways need more frequent checks than light indoor tracks.
Not as a like-for-like substitution. Welding changes the rail-end preparation, the expansion arrangement, the approval basis and the repair strategy. Where a continuous rail line is required, the joint method is a design decision made before the fishplate is specified.
By the time a project reaches ordering, the question is rarely "which fishplate" and usually "does this bar match the holes in that rail". Getting there takes four decisions in order: the rail section and its standard, the joint method, the drilling pattern, then the bar, bolt set and finish. The gap and the torque come after those, not before.
Full product scope for the bars themselves is documented on the crane rail fishplates page, which sets out the drilling, the sections it is matched to, and what travels with the delivery. If a project drawing names a hole pattern you are not sure about, or the rail already on site was drilled to a detail you no longer have, contact us with the rail designation and a photograph of the rail end and the enquiry can start from the right drawing.
Technical values quoted above are published catalogue and industry reference figures used to explain selection logic. They are not ATK test results for a specific batch. The applicable standard text and the approved project drawing govern tolerance, acceptance and supply.
This article was put together by the rail fastening and trackwork team at ATK, working from crane runway enquiries, workshop records and the photographs taken during production of the bars shown. The scope and status statements for YB/T 5055-2025, ASTM A759-21, DIN 536-1:1991-09 and 23G525 were checked against the national standards service platform, ASTM International, DIN Media and the national building standard design library. Supplier catalogue tables are reported as published by others; where a figure is a catalogue value rather than something we have measured, the text says so.